Short-Acting Insulins
Diabetes: Drug Class Navigation
Secretagogues
Insulin sensitizers
Alpha-glucosidase inh
Peptide analogs
Insulin Products
Regular insulin - humulin®, novolin®
CLINICAL PHARMACOLOGY Insulin promotes uptake of carbohydrates, proteins, and fats in most tissues. Also, insulin influences carbohydrate, protein, and fat metabolism by stimulating protein and free fatty acid synthesis, and by inhibiting release of free fatty acid from adipose cells. Insulin increases active glucose transport through muscle and adipose cellular membranes, and promotes conversion of intracellular glucose and free fatty acid to the appropriate storage forms (glycogen and triglyceride, respectively). Although the liver does not require active glucose transport, insulin increases hepatic glucose conversion to glycogen and suppresses hepatic glucose output. Even though the actions of exogenous insulin are identical to those of endogenous insulin, the ability to negatively affect hepatic glucose output differs on a unit per unit basis because a smaller quantity of an exogenous insulin dose reaches the portal vein. Administered insulin, including Novolin R, substitutes for inadequate endogenous insulin secretion and partially corrects the disordered metabolism and inappropriate hyperglycemia of diabetes mellitus, which are caused by either a deficiency or a reduction in the biologic effectiveness of insulin. When administered in appropriate doses at prescribed intervals to patients with diabetes mellitus, Novolin R temporarily restores their ability to metabolize carbohydrates, proteins and fats. Novolin R is a sterile, aqueous, and colorless solution of human insulin with a short duration of action. The pharmacologic effect of Novolin R begins approximately one-half (½) hour after subcutaneous administration. The effect is maximal between 2½ and 5 hours and terminates after approximately 8 hours. The onset of action of intravenous insulin is more rapid. INDICATIONS AND USAGE Novolin R may be administered intravenously under proper medical supervision in a clinical setting for glycemic control. CONTRAINDICATIONS WARNINGS Special care should be taken when the transfer is from a standard beef or mixed species insulin to a purified pork or human insulin. If a dosage adjustment is needed, it will usually become apparent either in the first few days or over a period of several weeks. Any change in treatment should be carefully monitored. PRECAUTIONS As with all insulin preparations, the time course of Novolin R action may vary in different individuals or at different times in the same individual and is dependent on dose, site of injection, blood supply, temperature, and physical activity. Adjustment of dosage of any insulin may be necessary if patients change their physical activity or their usual meal plan. Insulin requirements may be altered during illness, emotional disturbances, or other stresses. Novolin R should only be used if it is clear and colorless. Due to the risk of precipitation in some pump catheters, Novolin R is not recommended for use in insulin pumps. Hypoglycemia and hypokalemia - As with all insulin preparations, hypoglycemic and hypokalemic reactions may be associated with the administration of Novolin R, particularly via the IV route. Rapid changes in serum glucose levels may induce symptoms of hypoglycemia in persons with diabetes, regardless of the glucose value. Early warning symptoms of hypoglycemia may be different or less pronounced under certain conditions, such as long duration of diabetes, diabetic nerve disease, use of medications such as beta-blockers, or intensified diabetes control (see PRECAUTIONS, Drug Interactions). Such situations may result in severe hypoglycemia (and, possibly, loss of consciousness) prior to patients' awareness of hypoglycemia. Severe hypoglycemia can result in temporary or permanent impairment of brain function and death. Insulin stimulates potassium movement into the cells, possibly leading to hypokalemia that left untreated may cause respiratory paralysis, ventricular arrhythmia, and death. Since intravenously administered insulin has a rapid onset of action, increased attention to hypoglycemia and hypokalemia is necessary. Therefore, glucose and potassium levels must be monitored closely when Novolin R or any other insulin is administered intravenously. In certain cases, the nature and intensity of the warning symptoms of hypoglycemia may change. A few patients have reported that after being transferred to human insulin, the early warning symptoms for hypoglycemia had been less pronounced than they were with animal-source insulin. Hyperglycemia and ketosis - Hyperglycemia, diabetic ketoacidosis, or diabetic coma may develop if the patient takes less Novolin R than needed to control blood glucose levels. This could be due to insulin demand during illness or infection, neglect of diet, omission or improper administration of prescribed insulin doses. A developing ketoacidosis will be revealed by urine tests which show large amounts of sugar and acetone. The symptoms of polydipsia, polyurea, loss of appetite, fatigue, dry skin and deep and rapid breathing come on gradually, usually over a period of some hours or days. Severe sustained hyperglycemia may result in diabetic coma or death. Renal Impairment - As with other insulins, the dose requirements for Novolin R may be reduced in patients with renal impairment. Hepatic Impairment - As with other insulins, the dose requirements for Novolin R may be reduced in patients with hepatic impairment. Allergy Systemic Allergy - Less common, but potentially more serious, is generalized allergy to insulin, which may cause rash (including pruritus) over the whole body, shortness of breath, wheezing, reduction in blood pressure, rapid pulse, or sweating. Severe cases of generalized allergy, including anaphylactic reaction, may be life threatening. Localized reactions and generalized myalgias have been reported with the use of cresol as an injectable excipient. Usage in Pregnancy Information for patients Laboratory tests When Novolin R is administered intravenously, glucose and potassium levels must be closely monitored to avoid potentially fatal hypoglycemia and hypokalemia. Drug Interactions A number of substances affect glucose metabolism and may require insulin dose adjustment and particularly close monitoring.
Mixing of Insulins
DOSAGE AND ADMINISTRATION The average range of total daily insulin requirement for maintenance therapy in insulin-treated patients lies between 0.5 and 1.0 IU/kg. However, in pre-pubertal children it usually varies from 0.7 to 1.0 IU/kg, but can be much lower during the period of partial remission. In severe insulin resistance, e.g. during puberty or due to obesity, the daily insulin requirement may be substantially higher. Initial dosages for Type 2 diabetes patients are often lower, e.g. 0.2 to 0.4 IU/kg/day. Novolin R should be administered by subcutaneous injection in the abdominal wall, the thigh, the gluteal region or in the upper arm. Subcutaneous injection into the abdominal wall ensures a faster absorption than from other injection sites. Injection into a lifted skin fold minimizes the risk of intramuscular injection. Injection sites should be rotated within the same region. As with all insulins, the duration of action will vary according to the dose, injection site, blood flow, temperature, and level of physical activity. Intramuscular and intravenous administrations of Novolin R are possible under medical supervision with close monitoring of blood glucose and potassium levels to avoid hypoglycemia and hypokalemia. For intravenous use, Novolin R should be used at concentrations from 0.05 U/mL to 1.0 U/mL in infusion systems with the infusion fluids 0.9% sodium chloride, 5% dextrose, or 10% dextrose with 40 mmol/l potassium chloride using polypropylene infusion bags. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration, whenever solution and container permit. Never use Novolin R if it has become viscous (thickened) or cloudy; use it only if it is clear and colorless. Novolin R should not be used after the printed expiration date. RECOMMENDED STORAGE Infusion bags prepared as indicated under DOSAGE AND ADMINISTRATION are stable at room temperature for 24 hours. A certain amount of insulin will be initially adsorbed to the material of the infusion bag. Never use insulin after the expiration date which is printed on the label and carton. HOW SUPPLIED 10 mL vial NDC 0169-1833-11 3 mL PenFill cartridges* NDC 0169-3473-18 3 mL Novolin R InnoLet NDC 0169-2313-21 *Novolin R PenFill 3 mL cartridges are designed for use with Novo Nordisk 3 mL PenFill cartridge compatible insulin delivery devices, the NovoPen® 3 PenMate® and with NovoFine® disposable needles. |
Reference(s)
National Institutes of Health, U.S. National Library of Medicine, DailyMed Database.
Provides access to the latest drug monographs submitted to the Food and Drug Administration (FDA). Please review the latest applicable package insert for additional information and possible updates. A local search option of this data can be found here.