INDICATIONS
Technetium Tc 99m Albumin Aggregated Injection is a radioactive diagnostic agent indicated for:
- Lung scintigraphy as an adjunct in the evaluation of pulmonary perfusion in adults and pediatric patients.
- Scintigraphy of peritoneovenous shunt as an aid in the evaluation of its patency in adults.
DOSAGE AND ADMINISTRATION
Recommended Dosage And Administration
Adult Patients
The recommended intravenous dose range for adult patients for lung imaging is 37 MBq to 148 MBq (1 mCi to 4 mCi) and 200,000 to 700,000 particles of Technetium Tc 99m Albumin Aggregated Injection after preparation with oxidant-free Sodium Pertechnetate Tc 99m Injection.
The recommended intraperitoneal dosage range for adult patients for peritoneovenous shunt patency evaluation is 37 MBq to 111 MBq (1 mCi to 3 mCi) and 200,000 to 700,00 particles. Adequate measures should be taken to assure uniform mixing with peritoneal fluid. Serial images of both the shunt and target organ should be obtained and correlated with other clinical findings. Alternatively, the drug may be administered by percutaneous transtubal injection. The recommended percutaneous transtubal dosage range for adult patients is 12 MBq to 37 MBq (0.3 mCi to 1 mCi) in a volume not to exceed 0.5 mL.
The recommended range of particle numbers per single injection is 200,000 to 700,000 with the recommended number of approximately 350,000. Depending on the activity added and volume of the final reconstituted product, the volume of the dose may vary from 0.2 mL to 1.9 mL.
The number of particles available per dose of Technetium Tc 99m Albumin Aggregated Injection will vary depending on the physical decay of technetium Tc 99m that has occurred. The number of particles in any dose and volume to be administrated may be calculated as follows:
Where:
VTc = volume of solution added to reaction vial
D = desired dose to be administered in MBq (mCi)
C = concentration at calibration time of Sodium Pertechnetate solution to be added to the reaction vial in MBq/mL (mCi/mL)
Va = volume to be administered in mL
P = number of particles in dose to be administered
Fr = fraction of Technetium Tc 99m remaining after the time of calibration (Table 7)
N = number of particles per vial. The number of particles per vial for the lot is located on the vial label.
Pediatric Patients
In pediatric patients, the recommended intravenous dose for perfusion lung imaging is in the range of 0.925 MBq/kg to 1.85 MBq/kg (0.025 mCi/kg to 0.05 mCi/kg) of body weight; a usual dose is 1.11 MBq/kg (0.03 mCi/kg), except in newborns, in whom the administered dose should be 7.4 MBq to 18.5 MBq (0.2 mCi to 0.5 mCi). Not less than the minimum dose of 7.4 MBq (0.2 mCi) should be employed for this procedure. The number of particles varies with age and weight as shown in Table 1.
Table 1 - Pediatric Patients: Particle Number and Dose for Lung Scintigraphy
Age | Newborn | 1 year | 5 years | 10 years | 15 years |
Weight (kg) | 3.5 | | 12.1 | | 20.3 | | 33.5 | | 55 | |
Maximal recommended dose | MBq | mCi | MBq | mCi | MBq | mCi | MBq | mCi | MBq | mCi |
| 18.5 | 0.5 | 22.2 | 0.6 | 37 | 1 | 62.9 | 1.7 | 103.6 | 2.8 |
Range of particles administered | 10,000 to 50,000 | 50,000 to 150,000 | 200,000 to 300,000 | 200,000 to 300,000 | 200,000 to 700,000 |
Adults And Pediatric Patients
Visually inspect for particulate matter and discoloration prior to administration.
Measure the patient dose by a suitable radioactivity calibration system immediately prior to administration. Mix the contents of the vial by gentle inversion just prior to withdrawing a patient dose.
Mix the contents of the syringe just before injection. If blood is drawn into the syringe, any unnecessary delay prior to injection may lead to clot formation. For optimal results and because of rapid lung clearance of the radiopharmaceutical, position the patient under the imaging apparatus before administration. Slow injection is recommended. Lung imaging may begin immediately after intravenous injection of the radiopharmaceutical. Due to high kidney uptake, imaging later than one-half hour after administration will yield poor results.
Radiation Dosimetry
Adult Patients
The estimated absorbed radiation doses3 to an average adult patient (70 kg) from an intravenous administration of 148 MBq (4 mCi) of Technetium Tc 99m Albumin Aggregated Injection are shown in Table 2.
Table 2 - Adults: Radiation Absorbed Doses for Lung Scintigraphy
Organs | mGy/148 MBq | rad/4 mCi |
Total body | 0.6 | 0.06 |
Lungs | 8.8 | 0.88 |
Liver | 0.72 | 0.072 |
Spleen | 0.68 | 0.068 |
Kidneys | 0.44 | 0.044 |
Bladder wall | | |
3.5 hr. void | 1.2 | 0.12 |
4.8 hr. void | 2.2 | 0.22 |
Testes | | |
3.5 hr. void | 0.24 | 0.024 |
4.8 hr. void | 0.26 | 0.026 |
Ovaries | | |
3.5 hr. void | 0.3 | 0.03 |
4.8 hr. void | 0.34 | 0.034 |
Table 3 shows the radiation absorbed dose resulting from the intraperitoneal administration of 111 MBq (3 mCi) of Technetium Tc 99m Albumin Aggregated.
Table 3 - Adults: Radiation Absorbed Doses1 for Intraperitoneal Shunt Scintigraphy
Organs | Shunt Patency (Open) | Shunt Patency (Closed) |
| mGy | Rad | mGy | Rad |
Lung | 6.9 | 0.69 | 1.68 | 0.168 |
Ovaries & Testes | 0.18 to 0.3 | 0.018 to 0.03 | 1.68 | 0.168 |
Organs in the peritoneal cavity | - | - | 1.68 | 0.168 |
Total body | 0.36 | 0.036 | 0.57 | 0.057 |
*Assumptions: calculations for the radiation absorbed dose are based upon an effective half-time of 3 hours for the open shunt and a physical half-life of 6 hours for the closed shunt and an even distribution of the radiopharmaceutical in the peritoneal cavity with no biological clearance. |
Pediatric Patients
In pediatric patients, the radiation absorbed doses using the maximum recommended dose for lung imaging are based on 1.85 MBq (0.05 mCi) per kilogram of body weight (except in the newborns where the maximum recommended dose of 18.5 MBq (0.5 mCi) is used) and are shown in Table 4.
Table 4 - Pediatric Patients: Radiation Absorbed Doses for Lung Scintigraphy2,3
Age | Newborn | 1 year | 5 years | 10 years | 15 years |
| mGy | rad | mGy | Rad | mGy | rad | mGy | rad | mGy | Rad |
ORGANS | | | | | | | | | | |
Total body | 0.6 | 0.06 | 0.3 | 0.03 | 0.31 | 0.031 | 0.48 | 0.048 | 0.41 | 0.041 |
Lungs | 19 | 1.9 | 6.6 | 0.66 | 5.8 | 0.58 | 8.7 | 0.87 | 7.7 | 0.77 |
Liver | 1.4 | 0.14 | 0.6 | 0.06 | 0.62 | 0.062 | 1.8 | 0.18 | 1.2 | 0.12 |
Bladder wall | 2.1 | 0.21(1) | 1.5 | 0.15(1) | 3.1 | 0.31(2) | 3.9 | 0.39(2) | 4.1 | 0.41 |
Ovaries | 0.38 | 0.038 | 0.2 | 0.02 | 0.19 | 0.019 | 0.44 | 0.044 | 0.41 | 0.041 |
Testes | 0.31 | 0.031 | 0.13 | 0.013 | 0.19 | 0.019 | 0.2 | 0.02 | 0.36 | 0.036 |
(1) 2 hour voiding interval (2) 4.8 hour voiding interval |
Directions for Preparation
Procedural Precautions
- Perform all transfer and vial stopper entries using aseptic techniques.
- Wear waterproof gloves during the entire preparation procedure and during subsequent patient dose withdrawals from the Pulmotech MAA vial.
- Make all transfers of sodium pertechnetate Tc 99m injection solution during the preparation procedure with an adequately shielded syringe.
- Keep the Radioactive Preparation in the Dispensing Vial Shield described below (with cap in place) during the useful life of the Radioactive Preparation. Make all withdrawals and injections of the Radioactive Preparation with an adequately shielded syringe.
Procedure For The Preparation Of Technetium Tc 99m Albumin Aggregated
- If Pulmotech MAA vials are stored in the refrigerator, remove a vial and allow the contents to come to room temperature for approximately 5 minutes.
- Remove the protective disc from the Pulmotech MAA vial and swab the rubber septum with an alcohol swab or a suitable bacteriostatic agent to disinfect the surface.
- Place the vial in a suitable dispensing vial shield fitted with a shielded cap.
- Calculate the amount of sodium pertechnetate Tc 99m injection solution (2 mL to 13 mL) to be added to the Pulmotech MAA vial. During or prior to addition of technetium Tc 99m solution do not vent the Pulmotech MAA vial. In choosing the amount of technetium Tc 99m radioactivity to be used in the preparation of technetium Tc 99m albumin aggregated ensure that the radioactive dose will contain the desired number of MAA particles, while taking into account the number of patients, administered radioactive dose, radioactive decay. The recommended maximum amount of technetium Tc 99m to be added to the Pulmotech vial is 6.85 GBq (185 mCi). Calculate (see Recommended Dosage And Administration) the amount of radioactivity per vial required to be added to maintain the number of particles per dose within a recommended range [for adults 200,000 to 700,000, and for pediatric patients as per Table 1].
- After adding sodium pertechnetate Tc 99m injection solution to the Pulmotech MAA vial in the dispensing Vial shield (with cap in place), mix the contents by agitation and allow to stand for a minimum of 15 minutes at room temperature. Once prepared the product will have a turbid white appearance.
- Assay the product in a suitable dose calibrator and record the activity of the technetium Tc 99m albumin aggregated, total suspension volume, number of Tc 99m MAA particles, radioactive concentration, time and date of preparation, onto the radio-assay information label and attach it to the dispensing vial shield. 0.9% Sodium Chloride Injection, USP may be used as a diluent for the radiolabeled product to achieve the desired number of particles and radioactivity.
- Prior to withdrawing a dose, gently agitate the contents of the radiolabeled Pulmotech MAA vial to resuspend any settled technetium Tc 99m albumin aggregated particles. Failure to mix the reaction vial contents adequately before use may result in a non-homogenous suspension with a resulting non-uniform distribution of radioactivity in the lung. Withdrawals for administration must be made aseptically using a sterile needle (18 to 21 gauge) and syringe. Since the vials contain nitrogen to prevent oxidation of the complex, the vials should not be vented. If repeated withdrawals are made from the vial, the contents should not be replaced with air.
- Store the radiolabeled Pulmotech MAA vial in the dispensing vial shield in a refrigerator at 2° to 8°C (36° to 46°F). Use radiolabeled Pulmotech MAA within 18 hours from the time of preparation. Discard unused product.
HOW SUPPLIED
Dosage Forms And Strengths
Pulmotech MAA multiple-dose vial contains 2 mg of albumin aggregated as lyophilized powder. Radiolabeling with sodium pertechnetate Tc 99m injection solution provides an injectable suspension of technetium Tc 99m albumin aggregated. The radioactive dose for an adult is intended to contain 200,000 particles to 700,000 particles of technetium Tc 99m albumin aggregated with the target dose of approximately 350,000. Depending on the activity added and volume of the final reconstituted product, the volume of the dose may vary from 0.2 mL to 1.9 mL.
Storage And Handling
Pulmotech MAA (kit for the preparation of technetium Tc 99m albumin aggregated injection) is supplied either as a 5 vial clam shell (NDC 69945-139-20) or as a carton of 30 vials (NDC 69945-139-40).
Each 5 vial kit contains 5 multiple dose Pulmotech MAA vials, 1 prescribing information and 5 radio assay information labels. Each 30 vial carton contains 30 multiple dose Pulmotech MAA vials, 1 prescribing information and 30 radio assay information labels.
Storage And Disposal
Store Pulmotech MAA (kit for the preparation of Tc 99m albumin aggregated injection) at 2° to 25°C (36° to 77°F) before preparation (radiolabeling).
After, preparation with sodium pertechnetate Tc 99m injection, store radiolabeled technetium Tc 99m albumin aggregated Injection in a refrigerator at 2° to 8°C (36° to 46°F).
Do not use and discard radiolabeled Pulmotech MAA at 18 hours after preparation.
REFERENCES
1. Method of calculation: “S” Absorbed Dose per Unit Cumulated Activity for Selected Radionuclides and Organs, MIRD Pamphlet No. 11 (1975).
2. Used biologic data from Kaul et al., Berlin, 1973.
3. For the newborn, 1-year old, and 5-year old, the “S” values calculated form the preliminary phantoms of ORNL were used. The 10-year old, 15-year old and adult “S” values are from Henrichs, et al., Berlin, 1980.
Manufactured by: CIS bio International for Curium US LLC, 2703 Wagner Place, Maryland Heights, MO 63043. Revised: Mar 2020