[CRCL > 60 ml/min]: No changes.
[45-60 ml/min] or [Scr 1.6-2.0 mg/dL]: Bolus dose: 0.2 mg/kg IVP (over 15-20 seconds). Adjust rate to 50% of standard infusion rate: 0.075mg/kg/hour.
[30-44 ml/min] or [ Scr 2.1-3.0 mg/dL]: Bolus dose: 0.2 mg/kg IVP (over 15-20 seconds). Adjust rate to 30% of standard infusion rate: 0.045mg/kg/hour.
[15-29 ml/min] or [ Scr 3.1-6.0 mg/dL]: Bolus dose: 0.2 mg/kg IVP (over 15-20 seconds) Adjust rate to 15% of standard infusion rate: 0.0225mg/kg/hour.
[<15 ml/min] or [Scr>6.0 mg/dl]: Avoid or STOP infusion. |