GlobalRPh RX List - Viramune XR
- Product / population
- VIRAMUNE XR source discusses an immediate-release supplement; XR renal data are absent.
- Renal measure
- CrCl at least 20 mL/min without dialysis; below 20 not evaluated.
RX mirror: this is not independent corroboration of its underlying label. Check dated-label and formulation limitations.
Renal dosing, restrictions and evidence limits
The source states no adjustment at CrCl >=20 without dialysis, but also says VIRAMUNE XR itself has not been studied in renal dysfunction. For dialysis it specifically calls for an extra 200 mg of immediate-release VIRAMUNE after treatment, not an additional XR tablet. Below CrCl 20, pharmacokinetics have not been evaluated. Metabolite accumulation has uncertain significance. Keep this formulation and evidence limitation visible; the text is not proof of direct XR dialysis validation.