heparin
Ingredient or precise ingredient. A matching U.S. product is listed in FDA records. Marketing record
Dosing and clinical pharmacology
Heparin Sodium · INJECTION, SOLUTION · INTRAVENOUS
U.S. prescription labeling · NDA018916 · edition 35 · 2026-11-24.
Reviewed FDA label (XML) · Read complete label on DailyMed
Match the formulation, route and indication when using a label that covers several presentations.
Indications and uses
Heparin Sodium in Sodium Chloride Injection at a concentration of 2 units/mL is indicated as an anticoagulant to maintain catheter patency.
Dosage and administration
2.1 Preparation for Administration
Do not administer unless solution is clear and seal is intact. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration, whenever solution and container permit.
Warning: Do not use plastic containers in series connection. Such use could result in air embolism due to residual air being drawn from the primary container before administration of the fluid from the secondary container is completed.
Do not use Heparin Sodium in Sodium Chloride Injection as a “catheter lock flush” product.
Do not admix with other drugs. Discard unused portion.
To Open
Tear outer wrap and remove solution container.
Preparation for Administration
(Use aseptic technique)
- 1.Close flow control clamp of administration set.
- 2.Remove cover from outlet port at bottom of container.
- 3.Insert piercing pin of administration set into port with a twisting motion until the set is firmly seated.
NOTE: When using a vented administration set, replace bacterial retentive air filter with piercing pin cover. Insert piercing pin with twisting motion until shoulder of air filter housing rests against the outlet port flange. - 4.Suspend container from hanger.
- 5.Squeeze and release drip chamber to establish proper fluid level in chamber.
- 6.Attach venipuncture device to set.
- 7.Open clamp to expel air from set and venipuncture device. Close clamp.
- 8.Perform venipuncture.
- 9.Regulate rate of administration with flow control clamp.
2.2 Recommended Dosage for Maintenance of Catheter Patency
The recommended starting dose is 6 units per hour by intravenous infusion through an intravenous catheter to maintain catheter patency.
Mechanism of action
Heparin interacts with the naturally occurring plasma protein, antithrombin III, to induce a conformational change, which markedly enhances the serine protease activity of Antithrombin II, thereby inhibiting the activated coagulation factors involved in the closing sequence, particularly Xa and IIa. Small amounts of heparin inhibit Factor Xa, and larger amounts inhibit thrombin (Factor IIa).
Heparin also prevents the formation of a stable fibrin clot by inhibiting the activation of the fibrin stabilizing factor. Heparin does not have fibrinolytic activity; therefore, it will not lyse existing clots.
Open the existing GlobalRPh entry for heparin