Findings reference
Find a precise term among 2,612 objective findings.
Findings entries
Choose a page| Word | Plain-English search cue | Original note example | SOAP section | Writing task |
|---|---|---|---|---|
resection margin | cut edge of surgically removed tissue | The closest resection margin is recorded in millimeters. | Objective | Pathology, imaging detail and procedure findings |
sclerotic | abnormally hardened or dense in the stated tissue | The CT report describes a small sclerotic bone focus. | Objective | Pathology, imaging detail and procedure findings |
stranding | linear or streaky change in normally uniform fat on imaging | There is mild fat stranding near the incision. | Objective | Pathology, imaging detail and procedure findings |
subchondral | beneath the articular cartilage | A small subchondral cyst is visible at the medial joint surface. | Objective | Pathology, imaging detail and procedure findings |
suppurative | showing pus-forming inflammation | Histology describes acute suppurative inflammation. | Objective | Pathology, imaging detail and procedure findings |
trabecular | relating to the supporting lattice of bone | The MRI describes a trabecular injury pattern. | Objective | Pathology, imaging detail and procedure findings |
air trapping | incomplete emptying of air from the lungs on expiration | Expiratory images show patchy air trapping. | Objective | Pulmonary function, ventilation and oxygen delivery |
asynchrony | mismatch between patient effort and ventilator delivery | Waveform review shows intermittent patient-ventilator asynchrony. | Objective | Pulmonary function, ventilation and oxygen delivery |
auto-PEEP | intrinsic positive end-expiratory pressure due to incomplete exhalation | An expiratory hold demonstrated auto-PEEP. | Objective | Pulmonary function, ventilation and oxygen delivery |
bronchoalveolar lavage | fluid recovered after instillation into a lung segment for analysis | The bronchoalveolar lavage specimen was labeled with the sampled lobe. | Objective | Pulmonary function, ventilation and oxygen delivery |
bronchodilator response | change in measured airflow after a bronchodilator | The study reports the bronchodilator response using the laboratory criterion. | Objective | Pulmonary function, ventilation and oxygen delivery |
| tube or prongs used to deliver or access fluid or gas | Oxygen was delivered by nasal cannula. | Objective | Pulmonary function, ventilation and oxygen delivery | |
capnography | continuous measurement and display of exhaled carbon dioxide | The sedation record includes continuous capnography. | Objective | Pulmonary function, ventilation and oxygen delivery |
cuff leak | gas passing around an airway cuff under stated test conditions | The respiratory therapist documented the measured cuff leak. | Objective | Pulmonary function, ventilation and oxygen delivery |
dead space | ventilated volume that does not participate in gas exchange | The pulmonary report estimates physiologic dead space. | Objective | Pulmonary function, ventilation and oxygen delivery |
diffusing capacity | measure of gas transfer from alveoli into pulmonary capillary blood | The report lists diffusing capacity adjusted for the available hemoglobin. | Objective | Pulmonary function, ventilation and oxygen delivery |
driving pressure | plateau pressure minus total PEEP under the specified conditions | The ICU report gives driving pressure during passive ventilation. | Objective | Pulmonary function, ventilation and oxygen delivery |
end-tidal carbon dioxide | carbon dioxide measured near the end of expiration | The recorded end-tidal carbon dioxide is 36 mm Hg. | Objective | Pulmonary function, ventilation and oxygen delivery |
| volume exhaled during the first second of forced expiration | The report gives FEV1 in liters and as a percent predicted. | Objective | Pulmonary function, ventilation and oxygen delivery | |
FEV1/FVC | ratio of first-second forced expiratory volume to forced vital capacity | The postbronchodilator FEV1/FVC is recorded with its lower reference limit. | Objective | Pulmonary function, ventilation and oxygen delivery |
| fraction of inspired oxygen | The arterial sample was drawn on an FiO2 of 0.40. | Objective | Pulmonary function, ventilation and oxygen delivery | |
flow-volume loop | plot of flow against volume during a breathing maneuver | The inspiratory limb of the flow-volume loop appears flattened. | Objective | Pulmonary function, ventilation and oxygen delivery |
forced vital capacity | volume forcibly exhaled after full inspiration | The forced vital capacity is listed before and after bronchodilator. | Objective | Pulmonary function, ventilation and oxygen delivery |
functional residual capacity | lung gas volume at the end of a passive expiration | The pulmonary study includes functional residual capacity measured by plethysmography. | Objective | Pulmonary function, ventilation and oxygen delivery |
high-flow nasal cannula | heated humidified gas delivered through nasal prongs at high flow | The high-flow nasal cannula settings are recorded with the oxygen saturation. | Objective | Pulmonary function, ventilation and oxygen delivery |