WorkspaceFindings
PHP edition

Findings reference

Find a precise term among 2,612 objective findings.

Reset
Clinical findings
WordPlain-English search cueOriginal note exampleSOAP sectionWriting task
censored result
Link to this term
inequality reported instead of an exact numberThe censored result is recorded as less than 2 mg/L.ObjectiveDrug levels - analyte, specimen and reporting
chromatography
Link to this term
separation technique used before detection in some assaysThe assay used liquid chromatography before detection.ObjectiveDrug levels - analyte, specimen and reporting
corrected concentration
Link to this term
value adjusted mathematically using stated assumptionsThe corrected concentration was calculated and is identified separately from the measured value.ObjectiveDrug levels - analyte, specimen and reporting
critical result
Link to this term
value meeting the reporting laboratory's critical notification policyThe critical result was phoned to the covering clinician.ObjectiveDrug levels - analyte, specimen and reporting
cross-reactant
Link to this term
substance other than the intended analyte recognized by an assayThe laboratory identified a possible cross-reactant in the immunoassay.ObjectiveDrug levels - analyte, specimen and reporting
detection limit
Link to this term
lowest amount distinguishable from background under stated conditionsThe report lists the assay's detection limit alongside the qualitative result.ObjectiveDrug levels - analyte, specimen and reporting
dilution factor
Link to this term
number used to account for dilution in measurementThe reference laboratory documented the applied dilution factor.ObjectiveDrug levels - analyte, specimen and reporting
estimated concentration
Link to this term
value inferred from a model or calculationThe report labels the value as an estimated concentration.ObjectiveDrug levels - analyte, specimen and reporting
free concentration
amount of drug measured in the unbound fractionThe phenytoin free concentration is reported separately from total drug.ObjectiveDrug levels - analyte, specimen and reporting
icterus index
Link to this term
instrument estimate of bilirubin-related specimen discolorationThe icterus index exceeded the assay's stated interference threshold.ObjectiveDrug levels - analyte, specimen and reporting
immunoassay
test that uses antibody recognitionThe outside concentration was measured by immunoassay.ObjectiveDrug levels - analyte, specimen and reporting
laboratory flag
Link to this term
annotation applied by the reporting laboratoryA high laboratory flag accompanies the numerical result.ObjectiveDrug levels - analyte, specimen and reporting
lipemia
Link to this term
excess lipid causing a turbid specimenThe laboratory flagged lipemia in the submitted specimen.ObjectiveDrug levels - analyte, specimen and reporting
lower limit
Link to this term
lowest applicable value on a stated scale or intervalThe numeric result includes a qualifier at the reporting lower limit.ObjectiveDrug levels - analyte, specimen and reporting
mass concentration
Link to this term
mass of drug per volume of specimenThe mass concentration is reported in mg/L.ObjectiveDrug levels - analyte, specimen and reporting
mass spectrometry
Link to this term
method identifying or measuring analytes by mass-to-charge ratioThe laboratory measured the drug using liquid chromatography with tandem mass spectrometry.ObjectiveDrug levels - analyte, specimen and reporting
measured concentration
value obtained directly by assayThe measured concentration is recorded separately from the modeled estimate.ObjectiveDrug levels - analyte, specimen and reporting
molar concentration
Link to this term
amount of substance per volume in moles or related unitsThe molar concentration on the report is expressed in mmol/L.ObjectiveDrug levels - analyte, specimen and reporting
parent drug
original compound measured separately from its metabolitesThe parent drug and active metabolite appear on separate report lines.ObjectiveDrug levels - analyte, specimen and reporting
plasma concentration
Link to this term
amount of analyte per volume of plasmaThe plasma concentration was reported on the specimen collected yesterday.ObjectiveDrug levels - analyte, specimen and reporting
protein-bound fraction
Link to this term
portion of drug attached to circulating proteinsThe specialist report distinguishes the protein-bound fraction from the unbound portion.ObjectiveDrug levels - analyte, specimen and reporting
quantitation limit
Link to this term
boundary for reliable numerical measurementThe laboratory reported the value as below its lower quantitation limit.ObjectiveDrug levels - analyte, specimen and reporting
reportable range
interval over which the laboratory reports a validated measurementThe result exceeds the upper end of the assay's reportable range.ObjectiveDrug levels - analyte, specimen and reporting
sample integrity
Link to this term
condition of the specimen on receiptThe laboratory noted a sample integrity concern on arrival.ObjectiveDrug levels - analyte, specimen and reporting
serum level
Link to this term
concentration measured in serumThe serum level is reported in ng/mL on the original result.ObjectiveDrug levels - analyte, specimen and reporting
GlobalRPh   /   Clinical Note Coachv2.4

Bookmarked terms