Findings reference
Find a precise term among 2,612 objective findings.
| Word | Plain-English search cue | Original note example | SOAP section | Writing task |
|---|---|---|---|---|
regurgitant jet | backward flow through a valve seen on Doppler | A small central regurgitant jet is visible across the mitral valve. | Objective | Cardiac imaging, hemodynamics and rhythm details |
right atrial pressure | pressure in the right atrium, measured or estimated as stated | The echo report labels right atrial pressure as an estimate. | Objective | Cardiac imaging, hemodynamics and rhythm details |
septal motion | movement of the septum during the cardiac cycle | The report describes abnormal interventricular septal motion. | Objective | Cardiac imaging, hemodynamics and rhythm details |
shunt | abnormal or intentional passage of blood between compartments | The contrast study demonstrates a right-to-left shunt. | Objective | Cardiac imaging, hemodynamics and rhythm details |
sinus pause | temporary interruption of expected sinus impulses | The event monitor recorded a sinus pause during sleep. | Objective | Cardiac imaging, hemodynamics and rhythm details |
ST depression | ST segment lies below the reference baseline | The exercise tracing documents horizontal ST depression. | Objective | Cardiac imaging, hemodynamics and rhythm details |
ST elevation | ST segment lies above the reference baseline | The ECG shows mild ST elevation in the specified leads. | Objective | Cardiac imaging, hemodynamics and rhythm details |
strain | deformation of tissue, measured by a specified imaging method | Global longitudinal strain is reported on the echocardiogram. | Objective | Cardiac imaging, hemodynamics and rhythm details |
stroke volume | amount of blood ejected per ventricular beat | The measured stroke volume is reported in milliliters. | Objective | Cardiac imaging, hemodynamics and rhythm details |
systole | phase of ventricular contraction | The leaflet displacement is visible in late systole. | Objective | Cardiac imaging, hemodynamics and rhythm details |
tamponade physiology | hemodynamic effects of pressure on the heart from pericardial contents | The echocardiographer assessed for tamponade physiology in the presence of the effusion. | Objective | Cardiac imaging, hemodynamics and rhythm details |
| continuous remote monitoring of a physiologic signal | The overnight telemetry strip captured the episode. | Objective | Cardiac imaging, hemodynamics and rhythm details | |
U wave | small deflection after the T wave | A prominent U wave is visible in the precordial leads. | Objective | Cardiac imaging, hemodynamics and rhythm details |
valve area | calculated or measured area of a valve opening | The report lists the aortic valve area and its calculation method. | Objective | Cardiac imaging, hemodynamics and rhythm details |
vegetation | mass adherent to an endocardial structure in the appropriate context | The transesophageal study describes a suspected mitral vegetation. | Objective | Cardiac imaging, hemodynamics and rhythm details |
wedge pressure | catheter-derived pressure used to assess pulmonary venous-side filling conditions | The measured wedge pressure is documented with the tracing. | Objective | Cardiac imaging, hemodynamics and rhythm details |
active metabolite | metabolic product that has pharmacologic activity | The laboratory measured the active metabolite separately. | Objective | Drug levels - analyte, specimen and reporting |
aliquot volume | amount of specimen separated for analysis | The laboratory documented insufficient aliquot volume for the free level. | Objective | Drug levels - analyte, specimen and reporting |
amended result | laboratory result formally revised after initial reporting | The amended result lists the corrected specimen time. | Objective | Drug levels - analyte, specimen and reporting |
analyte | substance the assay measures | The analyte on the outside report is total phenytoin. | Objective | Drug levels - analyte, specimen and reporting |
assay interference | another substance or condition alters the measurement | The laboratory appended a comment about possible assay interference. | Objective | Drug levels - analyte, specimen and reporting |
assay method | technique used to obtain a reported concentration | The assay method is specified on the transplant laboratory report. | Objective | Drug levels - analyte, specimen and reporting |
below quantification | present or reported below a reliable numeric reporting limit | The analyte was reported as below quantification without an exact concentration. | Objective | Drug levels - analyte, specimen and reporting |
calibration curve | relationship between instrument response and known concentration | The laboratory report references the validated calibration curve. | Objective | Drug levels - analyte, specimen and reporting |
| material of known value used to establish assay response | The laboratory repeated analysis after checking the calibrator. | Objective | Drug levels - analyte, specimen and reporting |