Words for clinical notes
Search 5,131 terms by clinical wording, everyday description, or note example.
| Word | Plain-English search cue | Original note example | SOAP section | Writing task |
|---|---|---|---|---|
plasma free hemoglobin | hemoglobin present outside red cells in the plasma | Plasma free hemoglobin was repeated after review of the specimen quality. | Objective | Hematology and transfusion laboratory reporting |
immature granulocyte fraction | proportion of white cells classified as immature granulocytes | The immature granulocyte fraction was reviewed alongside the manual differential. | Objective | Hematology and transfusion laboratory reporting |
bone marrow cellularity | fraction of marrow space occupied by blood-forming cells | Bone marrow cellularity was interpreted against the age of the patient. | Objective | Hematology and transfusion laboratory reporting |
myeloid-to-erythroid ratio | relative abundance of myeloid and erythroid precursors in marrow | The myeloid-to-erythroid ratio was given with the pathologist's assessment of cellularity. | Objective | Hematology and transfusion laboratory reporting |
erythroid hyperplasia | increased proportion or number of red-cell precursors in marrow | Erythroid hyperplasia was noted in the aspirate report. | Objective | Hematology and transfusion laboratory reporting |
megakaryocytic hyperplasia | increased numbers of platelet-producing marrow cells | Megakaryocytic hyperplasia was described on the marrow core. | Objective | Hematology and transfusion laboratory reporting |
marrow blast percentage | proportion of counted marrow cells identified as blasts | The marrow blast percentage was reported separately from the peripheral blood count. | Objective | Hematology and transfusion laboratory reporting |
ring sideroblasts | marrow red-cell precursors with iron granules ringing the nucleus | Ring sideroblasts were identified on the marrow iron stain. | Objective | Hematology and transfusion laboratory reporting |
reticulin fibrosis | increased fine supporting fibers in marrow tissue | Reticulin fibrosis was graded on the stained core biopsy. | Objective | Hematology and transfusion laboratory reporting |
dry tap | marrow aspiration yielded little or no liquid marrow | A dry tap was documented and the core was submitted for review. | Objective | Hematology and transfusion laboratory reporting |
mixed-field agglutination | two apparent red-cell populations react differently during typing | Mixed-field agglutination was reported after recent transfusion. | Objective | Hematology and transfusion laboratory reporting |
ABO discrepancy | forward and reverse blood group results do not agree | The ABO discrepancy was referred to the transfusion laboratory for investigation. | Objective | Hematology and transfusion laboratory reporting |
antibody identification panel | panel of reagent red cells used to characterize an unexpected antibody | The antibody identification panel showed a pattern the blood bank interpreted with prior results. | Objective | Hematology and transfusion laboratory reporting |
indirect antiglobulin test | test for antibodies in plasma that can bind reagent red cells | The indirect antiglobulin test was positive on the pretransfusion sample. | Objective | Hematology and transfusion laboratory reporting |
elution study | testing material released from the surface of red cells | The elution study was performed to characterize the bound antibody. | Objective | Hematology and transfusion laboratory reporting |
autocontrol | patient plasma tested against the patient's own red cells | Autocontrol was included with the antibody investigation. | Objective | Hematology and transfusion laboratory reporting |
crossmatch incompatibility | donor and recipient testing showed an incompatible reaction | Crossmatch incompatibility was reported to the ordering team. | Objective | Hematology and transfusion laboratory reporting |
phenotype-matched red cells | donor red cells selected to match specified red-cell antigens | Phenotype-matched red cells were issued with the matched antigens listed. | Objective | Hematology and transfusion laboratory reporting |
irradiated blood component | blood product treated to inactivate donor lymphocytes | The irradiated blood component was verified against the transfusion request. | Objective | Hematology and transfusion laboratory reporting |
leukoreduced component | blood product processed to reduce donor white cells | The leukoreduced component was identified on the unit label. | Objective | Hematology and transfusion laboratory reporting |
washed red cells | red-cell component processed to remove much of the residual plasma | Washed red cells were documented in the transfusion record. | Objective | Hematology and transfusion laboratory reporting |
corrected count increment | platelet response to transfusion adjusted for body size and platelet dose | Corrected count increment was calculated using the timed posttransfusion count. | Objective | Hematology and transfusion laboratory reporting |
mixing study | clotting-time test after combining patient and normal plasma | The mixing study was recorded both immediately and after incubation. | Objective | Coagulation, antibodies and hemostasis studies |
inhibitor pattern | clotting abnormality with findings suggesting an inhibitor | The inhibitor pattern persisted after incubation in the mixing study. | Objective | Coagulation, antibodies and hemostasis studies |
Bethesda titer | measure of the activity of a specific clotting factor inhibitor | The Bethesda titer was supplied with the method and units. | Objective | Coagulation, antibodies and hemostasis studies |